ICS: Multiple Siemens Products Vulnerabilities

Severity

Medium

Analysis Summary

CVE-2024-39876 CVSS:4

Siemens SINEMA Remote Connect Server is vulnerable to a denial of service, caused by not properly handle log rotation. By sending a specially crafted request, a local attacker could exploit this vulnerability to cause a denial of service condition.

CVE-2023-32735 CVSS:6.5

Multiple Siemens products could allow a local authenticated attacker to execute arbitrary code on the system, caused by not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. By sending a specially crafted request, an attacker could exploit this vulnerability to execute arbitrary code on the system.

Impact

  • Denial of Service
  • Code Execution

Indicators of Compromise

CVE

  • CVE-2024-39876
  • CVE-2023-32735

Affected Vendors

Siemens

Affected Products

  • Siemens SINEMA Remote Connect Server 3.2
  • Siemens SIMATIC STEP 7 Safety V18 0
  • Siemens SIMATIC STEP 7 Safety V16 0
  • Siemens SIMATIC STEP 7 Safety V17 0
  • Siemens SIMATIC STEP 7 V16 0
  • Siemens SIMATIC STEP 7 V17 0

Remediation

Refer to Siemens Security Advisory for patch, upgrade or suggested workaround information.

CVE-2024-39876