Rewterz
Rewterz Threat Alert – Grandoreiro Banking Trojan Takes Over Device for Fraudulent Transactions
April 14, 2020
Rewterz
Rewterz Threat Advisory – ICS: Siemens Climatix Cross-Site Scripting Vulnerability
April 15, 2020

Rewterz Threat Advisory – ICS: Siemens SCALANCE and SIMATIC Denial of Service Vulnerability

Severity

Medium

Analysis Summary

A resource exhaustion vulnerability has been identified in scalance and simatic products of Siemens. The vulnerability is remotely exploitable and requires low skill to exploit. The VxWorks-based Profinet TCP stack can be forced to make resource-intense calls for every incoming packet, which can lead to a denial-of-service condition.

CVE-2019-19301 has been assigned to this vulnerability.

Impact

  • Resource Exhaustion
  • Denial of Service

Affected Vendors

Siemens

Affected Products

  • SCALANCE X-200 switch family (incl. SIPLUS NET variants): all versions
  • SCALANCE X-200IRT switch family (incl. SIPLUS NET variants): all versions
  • SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants): all versions
  • SIMATIC CP 443-1 (incl. SIPLUS NET variants): all versions
  • SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variants): all versions
  • SIMATIC RF180C: all versions
  • SIMATIC RF182C: all versions

Remediation

  • Updates are not yet available.
  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.